ClearFire-CE Condensing Boiler

ClearFire-CE Condensing Boilers

Built for the Future of Hydronics

Access the technical benchmarks and proprietary design features that drive 99% efficiency, variable-flow stability, and multi-fuel flexibility.

ClearFire®-CE Resources

These technical resources provide clear, practical reference material to support boiler selection, system design, and long-term performance decisions.

Hydronic Reference Guide

Your guide for a concise, at-a-glance overview of boiler options, controls, accessories, and core system design fundamentals.

ClearFire®-CE Brochure

Learn how high-mass condensing design delivers efficient, stable performance in real-world hydronic systems.

Hydronic Solutions Brochure

Explore how fully integrated boiler, skid, and control systems work together to improve efficiency, reliability, and total cost of ownership.

Duplex Stainless Steel

Quick access to a clear, data-backed comparison of duplex alloys versus 316L and why they deliver longer service life in boiler applications.

ClearFire-CE Unique Features

Duplex Stainless Steel Construction

Most competitors use 316L or 439 stainless steel. ClearFire uses Duplex LDX 2101.

High-Mass Fire-Tube Heat Exchanger

Eliminates the need for dedicated boiler pumps or minimum flow bypasses.

Dual Return Geometry

Unlike "single-inlet" boilers, ClearFire preserves temperature stratification.

TurboFer® / AluFer® Technology

ClearFire achieves high efficiency in a smaller footprint without the fragility of "mesh" burners.

3-Door Design

Lowest Total Cost of Ownership (TCO) due to ease of service.

Future-Proof

Hydrogen & RNG Ready. Meets tomorrow's decarbonization mandates today.

Duplex Stainless Steel

(LDX 2101)

Technical "Why"

Duplex has a dual-phase microstructure (austenite and ferrite). This combination offers 2x the yield strength of 316L and significantly higher resistance to Chloride Stress Corrosion Cracking (CSCC).

Application Value

In systems with unpredictable water chemistry or high chloride content, Duplex prevents the pitting and "localized" corrosion that leads to premature vessel failure in thinner-grade stainless boilers.

View Repair / Replacement Cost
Failure Level Typical Cost Range
Local weld repair attempt $4,000 – $12,000
Tube bundle replacement $18,000 – $45,000
Full heat exchanger replacement $25,000 – $60,000
Full boiler replacement (300–800 MBH range) $40,000 – $120,000+
Emergency rental boiler during outage $5,000 – $20,000 per month

High-Mass Fire-Tube

Technical "Why"

The large internal water volume provides thermal inertia. This prevents the "flash" heating and rapid cycling seen in low-mass water-tube boilers.

Application Value

Ideal for Variable-Primary Flow systems. The boiler is immune to "low flow" trips, reducing the complexity of the control sequence and the cost of external piping.

Dual Return Geometry

Technical "Why"

It features separate connections for high-temperature and low-temperature return loops. By keeping the coldest water at the bottom of the vessel, it ensures the flue gases are cooled below the dew point more consistently.

Application Value

This allows the boiler to stay in condensing mode even when high-temp loads (like DHW) are active, providing a 6% to 10% efficiency premium over boilers that blend return water.

TurboFer® Firetube Technology

Technical "Why"

The CFC-E utilizes a patented "tube-within-a-tube" design. An inner aluminum-alloy finned surface is die-fitted into a Duplex Stainless Steel tube. This creates an internal surface area 5x greater than standard smooth tubes and offers 10x the thermal conductivity of stainless steel alone.

Application Value

Aluminum conducts heat 10x faster than stainless steel. This allows for maximum energy extraction from flue gases in a compact, low-pressure-drop fire-tube design.

3-Door Design

Technical "Why"

Features a hinged front burner door and two rear access doors.

Application Value

Technicians can perform a full fireside inspection and tube cleaning without disconnecting the burner, gas train, or venting. Cuts annual maintenance labor by 40% compared to "cabinet-style" boilers that require total partial disassembly for service.

Future-Proof:
Hydrogen & RNG Ready

To meet aggressive decarbonization mandates, gas utilities are transitioning their infrastructure to Renewable Natural Gas (RNG) and Hydrogen Blends.

Technical "Why"

The ClearFire-CE is engineered with proprietary Ember controls and a burner design that accommodates the higher flame speeds and differing energy densities of these fuels. This allows the unit to fire 100% RNG or up to a 20% Hydrogen-and-Natural-Gas blend without requiring physical burner modifications or field retrofits.

Application Value

This "pre-certified" flexibility protects long-term investments from "stranded asset" risk as utility fuel streams evolve, while allowing facilities to meet immediate ESG goals by simply switching to sustainable fuel contracts.

Limited Time Promotion!

Recieve a FREE Blackstone Omnivore with the purchase of any ClearFire-CE boiler!

Get In Touch With Our Team

Submit a few details and our boiler specialists will follow up!

Boiler Inspection Checklist

Fill out the form below, and enjoy your download!